Gold Member Since 2011
Audited Supplier
MONTNETSRONGXIN TECHNOLOGY GROUP CO., LTD.

Converter, Energy Saving, Capacitor manufacturer / supplier in China, offering Customer Design Available--SVC, Capacitor, Converter, Inverter, Electronic, Energy Saving, Reactive Compensator, SVC, Thyristor Controlled Reactor, SVC and so on.

(/ )

Supplier Homepage Product Other Power Supply & Distribution Customer Design Available--SVC, Capacitor, Converter, Inverter, Electronic, Energy Saving

Customer Design Available--SVC, Capacitor, Converter, Inverter, Electronic, Energy Saving

FOB Price: Get Latest Price
Min. Order: 1 Piece
Production Capacity: 1000 Sets Per Year
Transport Package: Wooden Packing
Payment Terms: L/C, T/T
Product Catalog
recommend products
7 Products
Content
Product Image
Product Name
FOB Price
Port
Basic Info
  • Model NO.: MV
  • Capacity: 0-320Mvar
  • Specification: [6kv/10kv/35kv/27.5kv/55kv/110kv]
  • HS Code: 8504401990
  • Voltage: 6kv/10kv/35kv/27.5kv/55kv/110kv
  • Trademark: RXPE
  • Origin: Anshan City, Liaoning Province, China
Product Description
Customer Design Available--SVC, Capacitor, Converter, Inverter, Electronic, Energy Saving


[6kV/10kV/35kV/27.5kV/55kV/110kV]

ISO9001 Certificate Full Load Test
The biggest 66kV/10000kVA HV power station for SVG test
SVG

As the next generation product of SVC, STATCOM has superior performance in response speed, stability of voltage level, reducing system loss, increasing transmission capacity and improving transient voltage limit, reducing harmonics and decreasing occupation area etc. Since 2005, RXPE has begun to research and develop STATCOM with high-pressure large-capacity. In 2006, the STATCOM test platform has been completed successfully using DSP TMS320F2812. In 2007, the first STATCOM used for traction substation in China developed by RXPE.
Customer Design Available--SVC, Capacitor, Converter, Inverter, Electronic, Energy Saving
SVG -Application
-- Long-distance power transmission
- Stabilization of weak system voltage
- Reduced transmission loss
- Increased transmission capacity, make the existing power grid play maximum efficiency
- Increased transient steady limit
- Increased damping under small interference
- Better voltage control and stability
- Less power fluctuation
-- Secondary substation in city (66/110kv)
-- Hoist, and other heavy load
- Cause voltage level drop and voltage fluctuation in the power grid.
- Power factor is low.
- Transmission device will cause harmful high harmonic.
Above problems can be solved perfectly after installation of SVG of RXPE.
SVG Main Specialized Components
A. Transformer
B. Power unit
C. Input reactor
D. Control cabinet
E. Full digital control system
F. NMI integrative workstation
SVG-advantages
SVG is the most advanced var compensator technologically, which realizes an evolution of reactive power compensation mode based on voltage source converter. Big volume capacitors and reactors are no longer needed. SVG uses HV IGBT or IGCT with high switching frequency to realize reactive power regulation. Therefore, SVG has the following advantages compared with traditional compensation methods:
--Faster response speed
--Stronger voltage flicker restrain capability
--Wide operation range
--Low harmonic content
--Small volume

Customer Design Available--SVC, Capacitor, Converter, Inverter, Electronic, Energy Saving
SVG--Quality Guarantee
A Top quality IGBT module for traction
--German EUPEC top quality IGBT modules
--Super capability of bearing high current and voltage spikes.
B Low inductance power capacitor
--High rated voltage and current.
--Long service life and free maintenance.
--Advanced performance at high temperature condition.
C Unique cooling design
--Advanced heat pipe design with high efficiency heat radiation technology.
--Eliminate heat-island effect of HV IGBT thoroughly.
D Low Voltage SVG Test Platform
The SVG test platform utilizes US TI TMS320F2812 type DSP as key controller to realize the following tests:
--Manually generate adjustable capacitive or inductive reactive power.
--Automatically compensate reactive power.
--Stabilize grid voltage.
--Compensate load harmonics.
--Compensate load unbalance
--Compensate reactive power, harmonics and load unbalance simultaneously.
E International Level Components Test Center
Advanced components test center


Customer Design Available--SVC, Capacitor, Converter, Inverter, Electronic, Energy Saving
Send your message to this supplier
Avatar
Miss Wang
vice-general manager
*From:
To: Miss Wang
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now